• Skip to primary navigation
  • Skip to main content
Keller Manufacturing Logo

Keller Manufacturing

The Absolute Best in Crematories and Incinerators

  • Cremation
    • Human Cremation Equipment
      • Overview
      • KMH 1100-200
      • KMH 1100-300
      • KMH 1100-400
    • Animal Cremation Equipment
      • Overview
      • KMA 1200-75
      • KMA 1200-125
      • KMA 1200-200
      • KMA 1200-300
      • KMA 1200-400
      • KMA 1200-500 2C
      • KMA 1200-1000 4C
    • Cremation Accessory Equipment
      • Hydraulic Lift Table and Scale
      • Remains Processor
      • Processing Station
  • Waste Incineration
    • Overview
    • KMB 800
    • KMB 1200
    • KMB 1600
    • KMB 2400
    • KMB 5000
  • Parts and Supplies
  • Services
    • Equipment Maintenance, Service & Repairs
    • Equipment Installation, Commissioning and Operator Training
    • Equipment Financing
  • About
  • Contact
    • Sales
    • Service
    • Employment

Human Cremation Equipment Pricing

Need a free, no hassle price estimate on Human cremation equipment? Look no further than Keller Manufacturing. We are a global leader in human cremation equipment manufacturing and sales. We build custom machines and ship them to four dozen countries and 6 continents. Our full line of human cremation equipment will meet or exceed every need your facility has now, and well into the future.

No matter what you are in the market for, Keller has what you need at an extraordinary value. Don’t see what you’re looking for? No problem! We’ll build it, just for you, from the ground up!

  • Models
  • Equipment Comparison
  • FAQ
  • Accessories

Human Cremation Systems

Model image

KMH 1100-200

90 min / 200 lb/hr – 800 lb Capacity

Surprisingly feature-rich standard-sized cremator

Unit Detail
  • Unrivaled output  – minimal cooldown between cremations
  • 24 Hr. continuous operation  –  38” wide cremation chamber
  • Cremate up to eight (8) bodies in a twelve (12) hour period
  • A complete cremation every 90-120 minutes

Compare Features

Model image

KMH 1100-300

75 min / 150-300 lbs/hr – 1,000 lb Capacity

Outstanding performance in a mid-sized cremator

Unit Detail
  • Unrivaled output  – minimal cooldown between cremations
  • 24 Hr. continuous operation  –  38” wide cremation chamber
  • Cremate up to eight (8) bodies in a twelve (12) hour period
  • A complete cremation every 90-120 minutes

Compare Features

Model image

KMH 1100-400

60 min / 400 lb/hr – 1,200 lb Capacity

High performance, high volume large-sized cremator

Unit Detail
  • Unrivaled output  – minimal cooldown between cremations
  • 24 Hr. continuous operation  –  38” wide cremation chamber
  • Cremate up to eight (8) bodies in a twelve (12) hour period
  • A complete cremation every 90-120 minutes

Compare Features

Equipment Comparison

Model image
KMH 1100-200 Surprisingly feature-rich standard-sized cremator
Detail
Model image
KMH 1100-300 Outstanding performance in a mid-sized cremator
Detail
Model image
KMH 1100-400 High performance, high volume large-sized cremator
Detail
Performance Features      
Cremation Cycle Time 90 min 75 min 60 min
Burn Rate 200 lbs/hr 150-300 lbs/hr 150-400 lbs/hr
Capacity (Single Load) 800 lbs 1,000 lbs 1,200 lbs
24 Hr. continuous operation

Heavy-duty insulation and state-of-the-art drafting allows for continuous operation, no cool-downs between cremation cycles.

yes yes yes
Automatic PLC Operating System

The cremation cycle is controlled by a programmable logic control (PLC) system for complete automation from start to finish.

yes yes yes
Redundant Controls yes yes yes
Pollution Control System

Complete combustion is achieved in the Pollution Control Chamber, eliminating smoke and odor. All Keller Manufacturing cremators meet or exceed federal, state/province and local environmental regulations.

yes yes yes
Advanced combustion air distribution system with over-fire air yes yes yes
Standard Equipment Features      
Observation port for both chambers yes yes yes
Cast refractory lining through entire machine yes yes yes
3,000°F castable refractory “Hot Hearth” yes yes yes
Refractory lined stack and draft inducers yes yes yes
Powder coat paint finish with stainless steel trim

The top and rear compartments are finished with two coats of high-temperature, textured, black polyurethane. The front and side panels are powder coated in a claret color. The cremator is trimmed in stainless steel.

yes yes yes
Primary and Secondary digital temperature displays yes yes yes
Secondary chamber temperature recorder yes yes yes
10” color touch screen with redundant manual control panel

Visual confirmation of the system status is provided through a Color Touch Screen Panel which displays temperatures, elapsed time, burner operation and other functions. Continuous fuel and air modulation is automatically controlled by a time/temperature actuated system. Operator interface performed through the Color Touch Screen. A Temperature Chart Recorder (if applicable) is provided.

yes yes yes
Virtual service capable yes yes yes
Warranty One year limited One year limited One year limited
Safety Certifications

Keller Manufacturing cremation units comply with nationally recognized safety standards and have been tested and listed by Underwriters Laboratories, Inc. (UL)

MH47704 MH47704 MH47704
Service and Support      
Annual Evaluation and Maintenance (AEM) Optional Optional Optional
Control & combustion upgrades Optional Optional Optional
Equipment Installation Optional Optional Optional
Equipment Commissioning Included Included Included
Operator Training Included Included Included
Optional Upgrades      
O2 monitor control system for maximum efficiency Optional Optional Optional
Larger touch screen Optional Optional Optional
Full stainless steel outer skins Optional Optional Optional
Data acquisition Optional Optional Optional
Integrate control system into clients network Optional Optional Optional
Specifications      
Equipment Single Chamber Human Cremator; Natural Gas, Propane (LP) or Oil fired. Single Chamber Human Cremator; Natural Gas, Propane (LP) or Oil fired. Single Chamber Human Cremator; Natural Gas, Propane (LP) or Oil fired.
Construction Standards

The cremator shall be constructed of U.L. /CSA listed components and will meet or exceed nationally accepted incinerator construction standards as originally established per the Incinerator Institute of America (IIA) publication guidelines

  1. Primary chamber will not exceed 60% of total furnace volumes. Flue connection shall not be considered part of furnace volume.
  2. Flame supervision through continuous ultraviolet scanning flame detectors on all burners.
  3. High temperature refractory construction with air-cooled walls to prevent excessive heat radiation.
  4. Exhaust gas temperature reduction.
  1. Primary chamber will not exceed 60% of total furnace volumes. Flue connection shall not be considered part of furnace volume.
  2. Flame supervision through continuous ultraviolet scanning flame detectors on all burners.
  3. High temperature refractory construction with air-cooled walls to prevent excessive heat radiation.
  4. Exhaust gas temperature reduction.
  1. Primary chamber will not exceed 60% of total furnace volumes. Flue connection shall not be considered part of furnace volume.
  2. Flame supervision through continuous ultraviolet scanning flame detectors on all burners.
  3. High temperature refractory construction with air-cooled walls to prevent excessive heat radiation.
  4. Exhaust gas temperature reduction.
Cremator Dimensions      
Chamber volumes: Primary - 73 ft3 (2.07 m3)
Secondary - 71 ft3 (2.01 m3)
Primary - 92 F3 (2.61 M3)
Secondary - 83 F3 (2.35 M3)
Primary - 114 ft3 (3.23 m3)
Secondary - 101 ft3 (2.86 m3)
Primary Chamber: 94" L x 38" W x 31" H (2388 mm x 965 mm x 788 mm) 96" L x 46" W x 36" H (2438 mm x 1168 mm x 914 mm) 101” L x 52" W x 39" H (2565 mm x 1321 mm x 991 mm)
Structural footprint: 156" L x 62" W (3962 mm x 1575mm) 157” L x 70” W (3988 mm x 1778 mm) 169" L x 76" W (4293 mm x 1930 mm)
Over-all dimensions: 164½” L x 72" W (incl. Touch Screen) x 104½" H
(4178 mm L x 1829 mm W x 2654 mm H)
157” L x 81" W (incl. Touch Screen) x 114½” H
(3988 mm x 2058 mm x 2908 mm)
169" L x 87" W (W/ Control Panel) x 128" H (4293 mm L x 2210 mm W x 3251 mm H)
Power Charging Door      
Door Width 34½” (876 mm) 39” (991 mm) 42” (1067 mm)
Door Height 34½” (876 mm) 39” (991 mm) 42” (1067 mm)
Primary Chamber Opening      
Width 38” (965 mm) 46” (1168 mm) 52” (1321 mm)
Roof Arch Height 30” (762 mm) @ High Point – 27” (686 mm) @ Low Point 36” (914 mm) @ High Point – 31½” (800 mm) @ Low Point 39” (984 mm) @ High Point – 35” @ Low Point
Operating Temperature

Temperatures are determined as a result of federal, state or local permitting authority operating standards.

     
Typical primary chamber setting 1,000ºF-1,200ºF (538ºC - 648ºC) 1,000ºF-1,200ºF (538ºC - 648ºC) 1,000ºF-1,200ºF (538ºC - 648ºC)
Typical secondary chamber setting 1,600ºF-1,800ºF (871ºC - 982ºC) 1,600ºF-1,800ºF (871ºC - 982ºC) 1,600ºF-1,800ºF (871ºC - 982ºC)
Retention Time In excess of 1 second. In excess of 2 seconds In excess of 2 seconds.
Draft Induced via refractory lined draft inducer. Induced via refractory lined draft inducer. Induced via refractory lined draft inducer.
Shipping Weight 24,000 lbs. (10,886 kg) 30,000 lbs (13,607 kg) 34,000 lbs. (15,422 kg)
Emissions The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations. The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations. The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations.
Emission Control Secondary chamber equipped with one, 1,500,000 BTU/HR burner. Also equipped with an electronic exhaust gas scanner system which temporarily suspends operation of the primary chamber burner if the opacity of the exhaust gases reaches the maximum locally authorized level. Secondary chamber equipped with one 2,000,000 BTU/HR burner. Also equipped with an electronic exhaust gas scanner system which temporarily suspends operation of the primary chamber burner if the opacity of the exhaust gases reaches the maximum locally authorized level. Secondary chamber equipped with one 2,500,000 BTU/HR burner. Also equipped with an electronic exhaust gas scanner system which temporarily suspends operation of the primary chamber burner if the opacity of the exhaust gases reaches the maximum locally authorized level.
Steel Construction Specifications      
Structure The structure to be heavy 3" steel angle, square tube; 3/8" steel plate, seal welded construction. The structure to be heavy 3" steel angle, square tube; 3/8" steel plate, seal welded construction. The structure to be heavy 3" steel angle, square tube; 3/8" steel plate, seal welded construction.
Subfloor Subfloor to be 10 gauge steel plate, seal welded construction. Subfloor to be 3/16" steel plate, seal welded construction. Subfloor to be 3/16" steel plate, seal welded construction.
Exterior shell The exterior shell to be 14 gauge steel removable panels. The exterior shell to be 12 gauge steel removable panels. The exterior shell to be 12 gauge steel removable panels.
Interior shell Interior shell to be 10 gauge steel, seal welded construction. Interior shell to be 10 gauge steel, seal welded construction. Interior shell to be 10 gauge steel, seal welded construction.
Insulation & Refractory Specifications      
Hot Hearth 3000ºF (1650°C) abrasion resistant cast refractory monolithic cast 7" - 13" thick, 1 -1/2" recessed top and rounded, stressed arched bottom. 3000º F (1650° C) abrasion resistant cast refractory monolithic cast 7" - 13" thick, 1 -1/2" recessed top and rounded, stressed arched bottom. 3000ºF (1650°C) abrasion resistant cast refractory monolithic cast 7"-13" thick, 1 ½ ” recessed top and rounded, stressed arched bottom.
Chamber Floors 3000ºF (1650°C) abrasion resistant cast refractory, 5" thick on top of 2" 2400ºF (1316°C) light weight insulating castable. Chamber Floors: 3000º F (1650° C) abrasion resistant cast refractory, 5" thick on top of 2" 2400º F (1316° C) light weight insulating castable. 3000ºF (1650°C) abrasion resistant cast refractory, 5" thick on top of 2" 2400ºF (1316°C) lightweight insulating castable.
Chamber Ceilings 3000ºF(1650°C) cast refractory, monolithic cast, rounded, stressed arched, 5"-9" thick, topped by 2", 2400ºF (1360°C) light weight insulating castable. 3000º F (1650° C) cast refractory, monolithic cast, rounded, stressed arched, 5"-9" thick, topped by 2" 2400º F (1316° C) lightweight insulating castable. 3000ºF (1650°C) cast refractory, monolithic cast, rounded, stressed arched, 5"-9" thick, topped by 2", 2400ºF (1316°C) lightweight insulating castable.
Interior Walls 2800ºF (1538°C) alumina-silicate firebrick, 2 1/2" x 4 1/2" x 9”, all chambers are backed by 4" of 1900ºF (1038°C) ceramic fiber insulation. 2800º F (1538° C) alumina-silicate firebrick, 2½” x 4½" x 9", all chambers are backed by 4" of 1900º F (1038° C) ceramic fiber insulation. 2800ºF (1538°C) alumina-silicate firebrick, 2 1/2" x 4 1/2" x 9”, all chambers are backed by 4" (102 mm) of 1900ºF (1038°C) ceramic fiber insulation.
Stack Lined with 2-3" of 2200ºF (1205°C) insulating refractory. Lined with 2-3" of 2200º F (1205° C) insulating refractory. Lined with 2-3" (51 to 76 mm) of 2200ºF (1205°C) insulating refractory.
Skin Temperature Control Integral dual casing, completely air-cooled design to prevent excessive heat radiation. Integral dual casing, completely air-cooled design to prevent excessive heat radiation. Integral dual casing, completely air-cooled design to prevent excessive heat radiation.
Combustion Equipment      
Combustion Air One (1) Single or 3 phase, 208-230/460V, 17-15.5/7.6 amp, 7.5 hp air blower motor (1,700 CFM (158 CMM) One (1) 3 phase, 220/460V, 17-15.5/7.6 amp, 7.5 hp air blower motor (1,700 CFM (158 CMM) One (1) single or 3 phase, 220/460V, 17-15.5/7.6 amp, 7.5 hp air blower motor 1,700 CFM (158 CMM)
Primary Chamber One 500,000 BTU/hr. nozzle mix, gas-fired burner; Eclipse, North American, or equal. One 1,000,000 BTU/HR nozzle mix, gas-fired burner. Eclipse, North American, or equal. One 1,500,000 BTU/hr. nozzle mix, gas-fired burner; Eclipse, North American, or equal.
Secondary Chamber One, 1,500,000 BTU/HR modulating, nozzle mix, gas-fired Burner; Eclipse, North American, or equal. One, 2,000,000 BTU/HR modulating, nozzle mix, gas-fired burner. Eclipse, North American, or equal. One, 3,000,000 BTU/hr. modulating, nozzle mix, gas-fired burner. Eclipse, North American, or equal.
Burner Flame Safeguard Control supervision on each burner via a flame safeguard relay and ultra-violet light detector. Control supervision on each burner via a flame safeguard relay and ultra-violet light detector. Control supervision on each burner via a flame safeguard relay and ultra-violet light detector.
Low Air Pressure Safety Switch Interlocked to all burners. Interlocked to all burners. Interlocked to all burners.
Exhaust Gas Temperature Reduction Exhaust duct operating exit temperature: 900ºF (482ºC) Exhaust duct operating exit temperature: 900ºF (482ºC) Exhaust duct operating exit temperature: 900ºF (482ºC)
Hot Air Duct 10 gauge carbon steel, high temperature 2-3" refractory lining (51 -76 mm), pre-drilled flanges, 24" Outside Diameter, 28" (711 mm) at flanges. 10 gauge carbon steel, high temperature 2-3" refractory lining, pre-drilled flanges, 24" Outside Diameter, 28" at flanges. 10 gauge carbon steel, high temperature 2-3" (50 – 75 mm) refractory lining, pre-drilled flanges, 24” (610 mm) Outside Diameter, 28" (710 mm) at flanges.
Utility Requirements      
Gas      
Natural Gas Pressure 12-15" W.C. (304 to 381mm) 12-15" W.C. (304 to 381mm) 12-15" W.C. (304 to 381mm)
Propane Pressure 10-14" W.C. (288-355 mm) 11-14" W.C. (288-355 mm) 10-14" W.C. (288-355 mm)
Flow Rate Flow Rate: 2,000,000 BTU/hr. 3,000,000 BTU/hr Flow Rate: 4,000,000 BTU/hr.
Electrical      
Voltage 220/440 Volts 220/440 Volts 220/440 Volts
Phase Single or 3 Phase Single or 3 Phase Single or 3 Phase
Freq. 50/60 Hz 50/60 Hz 50/60 Hz
Amps 1 Phase: 70 Amps
3 Phase 230v/40 Amps, 440v/20 Amps
1 Phase: 70 Amps
3 Phase 230v/40 Amps, 440v/20 Amps
1 Phase: 70 Amps
3 Phase 230v/40 Amps, 440v/20 Amps
Documents      
Specifications KMH 1100-200 Specifications (PDF) KMH 1100-300 Specifications (PDF) KMH 1100-400 Specifications (PDF)
Machine Drawings KMH 1100-200 Drawings (PDF) KMH 1100-300 Drawings (PDF) KMH 1100-400 Drawings (PDF)
Model image
KMH 1100-200 Surprisingly feature-rich standard-sized cremator
Detail
Performance Features
Cremation Cycle Time 90 min
Burn Rate 200 lbs/hr
Capacity (Single Load) 800 lbs
24 Hr. continuous operation

Heavy-duty insulation and state-of-the-art drafting allows for continuous operation, no cool-downs between cremation cycles.

yes
Automatic PLC Operating System

The cremation cycle is controlled by a programmable logic control (PLC) system for complete automation from start to finish.

yes
Redundant Controls yes
Pollution Control System

Complete combustion is achieved in the Pollution Control Chamber, eliminating smoke and odor. All Keller Manufacturing cremators meet or exceed federal, state/province and local environmental regulations.

yes
Advanced combustion air distribution system with over-fire air yes
Standard Equipment Features
Observation port for both chambers yes
Cast refractory lining through entire machine yes
3,000°F castable refractory “Hot Hearth” yes
Refractory lined stack and draft inducers yes
Powder coat paint finish with stainless steel trim

The top and rear compartments are finished with two coats of high-temperature, textured, black polyurethane. The front and side panels are powder coated in a claret color. The cremator is trimmed in stainless steel.

yes
Primary and Secondary digital temperature displays yes
Secondary chamber temperature recorder yes
10” color touch screen with redundant manual control panel

Visual confirmation of the system status is provided through a Color Touch Screen Panel which displays temperatures, elapsed time, burner operation and other functions. Continuous fuel and air modulation is automatically controlled by a time/temperature actuated system. Operator interface performed through the Color Touch Screen. A Temperature Chart Recorder (if applicable) is provided.

yes
Virtual service capable yes
Warranty One year limited
Safety Certifications

Keller Manufacturing cremation units comply with nationally recognized safety standards and have been tested and listed by Underwriters Laboratories, Inc. (UL)

MH47704
Service and Support
Annual Evaluation and Maintenance (AEM) Optional
Control & combustion upgrades Optional
Equipment Installation Optional
Equipment Commissioning Included
Operator Training Included
Optional Upgrades
O2 monitor control system for maximum efficiency Optional
Larger touch screen Optional
Full stainless steel outer skins Optional
Data acquisition Optional
Integrate control system into clients network Optional
Specifications
Equipment Single Chamber Human Cremator; Natural Gas, Propane (LP) or Oil fired.
Construction Standards

The cremator shall be constructed of U.L. /CSA listed components and will meet or exceed nationally accepted incinerator construction standards as originally established per the Incinerator Institute of America (IIA) publication guidelines

  1. Primary chamber will not exceed 60% of total furnace volumes. Flue connection shall not be considered part of furnace volume.
  2. Flame supervision through continuous ultraviolet scanning flame detectors on all burners.
  3. High temperature refractory construction with air-cooled walls to prevent excessive heat radiation.
  4. Exhaust gas temperature reduction.
Cremator Dimensions  
Chamber volumes: Primary - 73 ft3 (2.07 m3)
Secondary - 71 ft3 (2.01 m3)
Primary Chamber: 94" L x 38" W x 31" H (2388 mm x 965 mm x 788 mm)
Structural footprint: 156" L x 62" W (3962 mm x 1575mm)
Over-all dimensions: 164½” L x 72" W (incl. Touch Screen) x 104½" H
(4178 mm L x 1829 mm W x 2654 mm H)
Power Charging Door  
Door Width 34½” (876 mm)
Door Height 34½” (876 mm)
Primary Chamber Opening  
Width 38” (965 mm)
Roof Arch Height 30” (762 mm) @ High Point – 27” (686 mm) @ Low Point
Operating Temperature

Temperatures are determined as a result of federal, state or local permitting authority operating standards.

 
Typical primary chamber setting 1,000ºF-1,200ºF (538ºC - 648ºC)
Typical secondary chamber setting 1,600ºF-1,800ºF (871ºC - 982ºC)
Retention Time In excess of 1 second.
Draft Induced via refractory lined draft inducer.
Shipping Weight 24,000 lbs. (10,886 kg)
Emissions The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations.
Emission Control Secondary chamber equipped with one, 1,500,000 BTU/HR burner. Also equipped with an electronic exhaust gas scanner system which temporarily suspends operation of the primary chamber burner if the opacity of the exhaust gases reaches the maximum locally authorized level.
Steel Construction Specifications  
Structure The structure to be heavy 3" steel angle, square tube; 3/8" steel plate, seal welded construction.
Subfloor Subfloor to be 10 gauge steel plate, seal welded construction.
Exterior shell The exterior shell to be 14 gauge steel removable panels.
Interior shell Interior shell to be 10 gauge steel, seal welded construction.
Insulation & Refractory Specifications  
Hot Hearth 3000ºF (1650°C) abrasion resistant cast refractory monolithic cast 7" - 13" thick, 1 -1/2" recessed top and rounded, stressed arched bottom.
Chamber Floors 3000ºF (1650°C) abrasion resistant cast refractory, 5" thick on top of 2" 2400ºF (1316°C) light weight insulating castable.
Chamber Ceilings 3000ºF(1650°C) cast refractory, monolithic cast, rounded, stressed arched, 5"-9" thick, topped by 2", 2400ºF (1360°C) light weight insulating castable.
Interior Walls 2800ºF (1538°C) alumina-silicate firebrick, 2 1/2" x 4 1/2" x 9”, all chambers are backed by 4" of 1900ºF (1038°C) ceramic fiber insulation.
Stack Lined with 2-3" of 2200ºF (1205°C) insulating refractory.
Skin Temperature Control Integral dual casing, completely air-cooled design to prevent excessive heat radiation.
Combustion Equipment  
Combustion Air One (1) Single or 3 phase, 208-230/460V, 17-15.5/7.6 amp, 7.5 hp air blower motor (1,700 CFM (158 CMM)
Primary Chamber One 500,000 BTU/hr. nozzle mix, gas-fired burner; Eclipse, North American, or equal.
Secondary Chamber One, 1,500,000 BTU/HR modulating, nozzle mix, gas-fired Burner; Eclipse, North American, or equal.
Burner Flame Safeguard Control supervision on each burner via a flame safeguard relay and ultra-violet light detector.
Low Air Pressure Safety Switch Interlocked to all burners.
Exhaust Gas Temperature Reduction Exhaust duct operating exit temperature: 900ºF (482ºC)
Hot Air Duct 10 gauge carbon steel, high temperature 2-3" refractory lining (51 -76 mm), pre-drilled flanges, 24" Outside Diameter, 28" (711 mm) at flanges.
Utility Requirements
Gas  
Natural Gas Pressure 12-15" W.C. (304 to 381mm)
Propane Pressure 10-14" W.C. (288-355 mm)
Flow Rate Flow Rate: 2,000,000 BTU/hr.
Electrical  
Voltage 220/440 Volts
Phase Single or 3 Phase
Freq. 50/60 Hz
Amps 1 Phase: 70 Amps
3 Phase 230v/40 Amps, 440v/20 Amps
Documents
Specifications KMH 1100-200 Specifications (PDF)
Machine Drawings KMH 1100-200 Drawings (PDF)
Model image
KMH 1100-300 Outstanding performance in a mid-sized cremator
Detail
Performance Features
Cremation Cycle Time 75 min
Burn Rate 150-300 lbs/hr
Capacity (Single Load) 1,000 lbs
24 Hr. continuous operation

Heavy-duty insulation and state-of-the-art drafting allows for continuous operation, no cool-downs between cremation cycles.

yes
Automatic PLC Operating System

The cremation cycle is controlled by a programmable logic control (PLC) system for complete automation from start to finish.

yes
Redundant Controls yes
Pollution Control System

Complete combustion is achieved in the Pollution Control Chamber, eliminating smoke and odor. All Keller Manufacturing cremators meet or exceed federal, state/province and local environmental regulations.

yes
Advanced combustion air distribution system with over-fire air yes
Standard Equipment Features
Observation port for both chambers yes
Cast refractory lining through entire machine yes
3,000°F castable refractory “Hot Hearth” yes
Refractory lined stack and draft inducers yes
Powder coat paint finish with stainless steel trim

The top and rear compartments are finished with two coats of high-temperature, textured, black polyurethane. The front and side panels are powder coated in a claret color. The cremator is trimmed in stainless steel.

yes
Primary and Secondary digital temperature displays yes
Secondary chamber temperature recorder yes
10” color touch screen with redundant manual control panel

Visual confirmation of the system status is provided through a Color Touch Screen Panel which displays temperatures, elapsed time, burner operation and other functions. Continuous fuel and air modulation is automatically controlled by a time/temperature actuated system. Operator interface performed through the Color Touch Screen. A Temperature Chart Recorder (if applicable) is provided.

yes
Virtual service capable yes
Warranty One year limited
Safety Certifications

Keller Manufacturing cremation units comply with nationally recognized safety standards and have been tested and listed by Underwriters Laboratories, Inc. (UL)

MH47704
Service and Support
Annual Evaluation and Maintenance (AEM) Optional
Control & combustion upgrades Optional
Equipment Installation Optional
Equipment Commissioning Included
Operator Training Included
Optional Upgrades
O2 monitor control system for maximum efficiency Optional
Larger touch screen Optional
Full stainless steel outer skins Optional
Data acquisition Optional
Integrate control system into clients network Optional
Specifications
Equipment Single Chamber Human Cremator; Natural Gas, Propane (LP) or Oil fired.
Construction Standards

The cremator shall be constructed of U.L. /CSA listed components and will meet or exceed nationally accepted incinerator construction standards as originally established per the Incinerator Institute of America (IIA) publication guidelines

  1. Primary chamber will not exceed 60% of total furnace volumes. Flue connection shall not be considered part of furnace volume.
  2. Flame supervision through continuous ultraviolet scanning flame detectors on all burners.
  3. High temperature refractory construction with air-cooled walls to prevent excessive heat radiation.
  4. Exhaust gas temperature reduction.
Cremator Dimensions  
Chamber volumes: Primary - 92 F3 (2.61 M3)
Secondary - 83 F3 (2.35 M3)
Primary Chamber: 96" L x 46" W x 36" H (2438 mm x 1168 mm x 914 mm)
Structural footprint: 157” L x 70” W (3988 mm x 1778 mm)
Over-all dimensions: 157” L x 81" W (incl. Touch Screen) x 114½” H
(3988 mm x 2058 mm x 2908 mm)
Power Charging Door  
Door Width 39” (991 mm)
Door Height 39” (991 mm)
Primary Chamber Opening  
Width 46” (1168 mm)
Roof Arch Height 36” (914 mm) @ High Point – 31½” (800 mm) @ Low Point
Operating Temperature

Temperatures are determined as a result of federal, state or local permitting authority operating standards.

 
Typical primary chamber setting 1,000ºF-1,200ºF (538ºC - 648ºC)
Typical secondary chamber setting 1,600ºF-1,800ºF (871ºC - 982ºC)
Retention Time In excess of 2 seconds
Draft Induced via refractory lined draft inducer.
Shipping Weight 30,000 lbs (13,607 kg)
Emissions The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations.
Emission Control Secondary chamber equipped with one 2,000,000 BTU/HR burner. Also equipped with an electronic exhaust gas scanner system which temporarily suspends operation of the primary chamber burner if the opacity of the exhaust gases reaches the maximum locally authorized level.
Steel Construction Specifications  
Structure The structure to be heavy 3" steel angle, square tube; 3/8" steel plate, seal welded construction.
Subfloor Subfloor to be 3/16" steel plate, seal welded construction.
Exterior shell The exterior shell to be 12 gauge steel removable panels.
Interior shell Interior shell to be 10 gauge steel, seal welded construction.
Insulation & Refractory Specifications  
Hot Hearth 3000º F (1650° C) abrasion resistant cast refractory monolithic cast 7" - 13" thick, 1 -1/2" recessed top and rounded, stressed arched bottom.
Chamber Floors Chamber Floors: 3000º F (1650° C) abrasion resistant cast refractory, 5" thick on top of 2" 2400º F (1316° C) light weight insulating castable.
Chamber Ceilings 3000º F (1650° C) cast refractory, monolithic cast, rounded, stressed arched, 5"-9" thick, topped by 2" 2400º F (1316° C) lightweight insulating castable.
Interior Walls 2800º F (1538° C) alumina-silicate firebrick, 2½” x 4½" x 9", all chambers are backed by 4" of 1900º F (1038° C) ceramic fiber insulation.
Stack Lined with 2-3" of 2200º F (1205° C) insulating refractory.
Skin Temperature Control Integral dual casing, completely air-cooled design to prevent excessive heat radiation.
Combustion Equipment  
Combustion Air One (1) 3 phase, 220/460V, 17-15.5/7.6 amp, 7.5 hp air blower motor (1,700 CFM (158 CMM)
Primary Chamber One 1,000,000 BTU/HR nozzle mix, gas-fired burner. Eclipse, North American, or equal.
Secondary Chamber One, 2,000,000 BTU/HR modulating, nozzle mix, gas-fired burner. Eclipse, North American, or equal.
Burner Flame Safeguard Control supervision on each burner via a flame safeguard relay and ultra-violet light detector.
Low Air Pressure Safety Switch Interlocked to all burners.
Exhaust Gas Temperature Reduction Exhaust duct operating exit temperature: 900ºF (482ºC)
Hot Air Duct 10 gauge carbon steel, high temperature 2-3" refractory lining, pre-drilled flanges, 24" Outside Diameter, 28" at flanges.
Utility Requirements
Gas  
Natural Gas Pressure 12-15" W.C. (304 to 381mm)
Propane Pressure 11-14" W.C. (288-355 mm)
Flow Rate 3,000,000 BTU/hr
Electrical  
Voltage 220/440 Volts
Phase Single or 3 Phase
Freq. 50/60 Hz
Amps 1 Phase: 70 Amps
3 Phase 230v/40 Amps, 440v/20 Amps
Documents
Specifications KMH 1100-300 Specifications (PDF)
Machine Drawings KMH 1100-300 Drawings (PDF)
Model image
KMH 1100-400 High performance, high volume large-sized cremator
Detail
Performance Features
Cremation Cycle Time 60 min
Burn Rate 150-400 lbs/hr
Capacity (Single Load) 1,200 lbs
24 Hr. continuous operation

Heavy-duty insulation and state-of-the-art drafting allows for continuous operation, no cool-downs between cremation cycles.

yes
Automatic PLC Operating System

The cremation cycle is controlled by a programmable logic control (PLC) system for complete automation from start to finish.

yes
Redundant Controls yes
Pollution Control System

Complete combustion is achieved in the Pollution Control Chamber, eliminating smoke and odor. All Keller Manufacturing cremators meet or exceed federal, state/province and local environmental regulations.

yes
Advanced combustion air distribution system with over-fire air yes
Standard Equipment Features
Observation port for both chambers yes
Cast refractory lining through entire machine yes
3,000°F castable refractory “Hot Hearth” yes
Refractory lined stack and draft inducers yes
Powder coat paint finish with stainless steel trim

The top and rear compartments are finished with two coats of high-temperature, textured, black polyurethane. The front and side panels are powder coated in a claret color. The cremator is trimmed in stainless steel.

yes
Primary and Secondary digital temperature displays yes
Secondary chamber temperature recorder yes
10” color touch screen with redundant manual control panel

Visual confirmation of the system status is provided through a Color Touch Screen Panel which displays temperatures, elapsed time, burner operation and other functions. Continuous fuel and air modulation is automatically controlled by a time/temperature actuated system. Operator interface performed through the Color Touch Screen. A Temperature Chart Recorder (if applicable) is provided.

yes
Virtual service capable yes
Warranty One year limited
Safety Certifications

Keller Manufacturing cremation units comply with nationally recognized safety standards and have been tested and listed by Underwriters Laboratories, Inc. (UL)

MH47704
Service and Support
Annual Evaluation and Maintenance (AEM) Optional
Control & combustion upgrades Optional
Equipment Installation Optional
Equipment Commissioning Included
Operator Training Included
Optional Upgrades
O2 monitor control system for maximum efficiency Optional
Larger touch screen Optional
Full stainless steel outer skins Optional
Data acquisition Optional
Integrate control system into clients network Optional
Specifications
Equipment Single Chamber Human Cremator; Natural Gas, Propane (LP) or Oil fired.
Construction Standards

The cremator shall be constructed of U.L. /CSA listed components and will meet or exceed nationally accepted incinerator construction standards as originally established per the Incinerator Institute of America (IIA) publication guidelines

  1. Primary chamber will not exceed 60% of total furnace volumes. Flue connection shall not be considered part of furnace volume.
  2. Flame supervision through continuous ultraviolet scanning flame detectors on all burners.
  3. High temperature refractory construction with air-cooled walls to prevent excessive heat radiation.
  4. Exhaust gas temperature reduction.
Cremator Dimensions  
Chamber volumes: Primary - 114 ft3 (3.23 m3)
Secondary - 101 ft3 (2.86 m3)
Primary Chamber: 101” L x 52" W x 39" H (2565 mm x 1321 mm x 991 mm)
Structural footprint: 169" L x 76" W (4293 mm x 1930 mm)
Over-all dimensions: 169" L x 87" W (W/ Control Panel) x 128" H (4293 mm L x 2210 mm W x 3251 mm H)
Power Charging Door  
Door Width 42” (1067 mm)
Door Height 42” (1067 mm)
Primary Chamber Opening  
Width 52” (1321 mm)
Roof Arch Height 39” (984 mm) @ High Point – 35” @ Low Point
Operating Temperature

Temperatures are determined as a result of federal, state or local permitting authority operating standards.

 
Typical primary chamber setting 1,000ºF-1,200ºF (538ºC - 648ºC)
Typical secondary chamber setting 1,600ºF-1,800ºF (871ºC - 982ºC)
Retention Time In excess of 2 seconds.
Draft Induced via refractory lined draft inducer.
Shipping Weight 34,000 lbs. (15,422 kg)
Emissions The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations.
Emission Control Secondary chamber equipped with one 2,500,000 BTU/HR burner. Also equipped with an electronic exhaust gas scanner system which temporarily suspends operation of the primary chamber burner if the opacity of the exhaust gases reaches the maximum locally authorized level.
Steel Construction Specifications  
Structure The structure to be heavy 3" steel angle, square tube; 3/8" steel plate, seal welded construction.
Subfloor Subfloor to be 3/16" steel plate, seal welded construction.
Exterior shell The exterior shell to be 12 gauge steel removable panels.
Interior shell Interior shell to be 10 gauge steel, seal welded construction.
Insulation & Refractory Specifications  
Hot Hearth 3000ºF (1650°C) abrasion resistant cast refractory monolithic cast 7"-13" thick, 1 ½ ” recessed top and rounded, stressed arched bottom.
Chamber Floors 3000ºF (1650°C) abrasion resistant cast refractory, 5" thick on top of 2" 2400ºF (1316°C) lightweight insulating castable.
Chamber Ceilings 3000ºF (1650°C) cast refractory, monolithic cast, rounded, stressed arched, 5"-9" thick, topped by 2", 2400ºF (1316°C) lightweight insulating castable.
Interior Walls 2800ºF (1538°C) alumina-silicate firebrick, 2 1/2" x 4 1/2" x 9”, all chambers are backed by 4" (102 mm) of 1900ºF (1038°C) ceramic fiber insulation.
Stack Lined with 2-3" (51 to 76 mm) of 2200ºF (1205°C) insulating refractory.
Skin Temperature Control Integral dual casing, completely air-cooled design to prevent excessive heat radiation.
Combustion Equipment  
Combustion Air One (1) single or 3 phase, 220/460V, 17-15.5/7.6 amp, 7.5 hp air blower motor 1,700 CFM (158 CMM)
Primary Chamber One 1,500,000 BTU/hr. nozzle mix, gas-fired burner; Eclipse, North American, or equal.
Secondary Chamber One, 3,000,000 BTU/hr. modulating, nozzle mix, gas-fired burner. Eclipse, North American, or equal.
Burner Flame Safeguard Control supervision on each burner via a flame safeguard relay and ultra-violet light detector.
Low Air Pressure Safety Switch Interlocked to all burners.
Exhaust Gas Temperature Reduction Exhaust duct operating exit temperature: 900ºF (482ºC)
Hot Air Duct 10 gauge carbon steel, high temperature 2-3" (50 – 75 mm) refractory lining, pre-drilled flanges, 24” (610 mm) Outside Diameter, 28" (710 mm) at flanges.
Utility Requirements
Gas  
Natural Gas Pressure 12-15" W.C. (304 to 381mm)
Propane Pressure 10-14" W.C. (288-355 mm)
Flow Rate Flow Rate: 4,000,000 BTU/hr.
Electrical  
Voltage 220/440 Volts
Phase Single or 3 Phase
Freq. 50/60 Hz
Amps 1 Phase: 70 Amps
3 Phase 230v/40 Amps, 440v/20 Amps
Documents
Specifications KMH 1100-400 Specifications (PDF)
Machine Drawings KMH 1100-400 Drawings (PDF)

Frequently Asked Questions

Do You Provide Start Up & Training?

Yes. Upon notification from the customer that the installation is complete, a Keller technician will travel to the facility to place the unit in operation. Our technician will spend up to three days at the site curing the refractory lining of the cremator, starting up the unit, adjusting air and gas settings and proving all systems. To complete the start-up the technician will perform a cremation and train crematory personnel in the simple operation. It is important that a cremation be available for training at start up.

What Do You Provide For Warranty & Service?

We warrant our equipment to be free of defects in workmanship for two years and our staff is available around the clock to provide technical assistance and operating support. The Operating & Maintenance Manual describes the function of all components and is invaluable for troubleshooting. We stock a complete line of replacement parts and major components and our Service Department is available for service and repairs on all makes of cremation equipment.

Is Your Operating System Automatic?

Standard to the KMH-1100 line of cremators is a proven and tested automatic operating system with color touch screen control. Load the body and container in the primary chamber, set the timer and press the Start button to begin the cycle. The system is programmed to begin a 45-second purge cycle before igniting the secondary chamber burner to start the preheat cycle. Once the proper temperature is reached in the pollution control chamber, the primary burner is ignited to begin the cremation cycle. Upon completion of the cremation the system advances to the cool down cycle at which time the burners shut down and clean out of the cremated remains can be made.

Do We Have To Worry About Any Visible Emissions?0

Complete combustion is achieved in the KMH-1100 line’s temperature-controlled large secondary chamber. Greater than 99% of volatilized carbon created in the combustion process is converted to carbon dioxide. In addition, an Opacity Sensor is located at the base of the stack to monitor the clarity of the exhaust gases. Once the exhaust gases reach 20% opacity, the PLC automatically shuts down the primary burner and adjusts combustion air supply to slow the combustion rate and prevent visible emissions from exiting the stack.

Cremation Lift Table: Side Angle

Human Cremation Accessory Equipment

Complimentary products that simplify and professionalize your process to assure you are applying the industry’s “Best Practices.”

Cremation Accessory Equipment

We have a 60 year history of manufacturing and servicing industry equipment worldwide.

Keller has gained a reputation for being a worldwide leader in the design and manufacture of combustion systems. Based in Central Florida, we have manufactured and put into operation over two thousand (2,000) installations worldwide.

Great work quality and everyone is friendly

bradford pry Avatar bradford pry

Raymond Bounds Avatar Raymond Bounds

We are proud members of CANA and ICCFA:

CANA Logo
ICCFA Logo

How may we help you?

Our experienced professional team can help you with any cremation or incineration project anywhere in the world. 

Request InfoRequest a CallSchedule Service

Need a quote or looking for more info? We can help.

Periodic news, updates, and special offers from Keller Manufacturing direct to your inbox.
Loading

We’ll call you back at your convenience.

Periodic news, updates, and special offers from Keller Manufacturing direct to your inbox.
Loading

Schedule a Service Appointment

To schedule service or consult with a Keller Mechanical Technician, give us a call, or fill out the following form and a member of our staff will be in touch with you shortly.

About Your Request

Periodic news, updates, and special offers from Keller Manufacturing direct to your inbox.
Loading
Request Information

Need a quote or looking for more info? We can help.

Periodic news, updates, and special offers from Keller Manufacturing direct to your inbox.
Loading
Request a Call

We’ll call you back at your convenience.

Periodic news, updates, and special offers from Keller Manufacturing direct to your inbox.
Loading
Schedule Service

Schedule a Service Appointment

To schedule service or consult with a Keller Mechanical Technician, give us a call, or fill out the following form and a member of our staff will be in touch with you shortly.

About Your Request

Periodic news, updates, and special offers from Keller Manufacturing direct to your inbox.
Loading

Prefer a more traditional method?

Give us a call, shoot us an email, or send us some snail mail. We’ll be glad to hear from you.

(863) 937-8928

Email Sales

4442 Holden Rd
Lakeland, FL 33811

You are here: Home / Landing Pages / Human Cremation Equipment Pricing

Coordinate with our expert staff on your facility's requirements. Contact Us

Keller Manufacturing

Copyright © 2025Keller Manufacturing, Inc. · Privacy Policy · Contact Us