Waste Incineration Equipment Sales and Service
Keller Manufacturing offers a complete range of incineration equipment and services from the manufacturing of incinerators, thermal and recuperative thermal oxidizers, stacks, breaching, pollution control equipment and charging systems, to complete rebuilds of existing systems, technical consulting and engineering, waste analysis, environmental permitting and testing/certification.
Industry Expertise
We are experienced in the areas of medical, pathological and solid waste incineration as well as in the application of our technologies to other industries such as chemical, industrial, VOC and liquid waste treatment as well.
A Full Line of Equipment
All of our incineration equipment operates on a geometrically similar construction and design principal and can be configured for solids, liquids and gaseous wastes, while providing features and benefits which cannot be matched in total by any other equipment manufacturer.
Emissions requirements
When emissions requirements dictate that more than the effects of good combustion are needed, we are positioned and experienced to supply integrated systems and/or retrofit existing systems to meet virtually any demand.
Incinerators For Sale
Standard “Hot Hearth” systems
Our standard line of solid waste incineration equipment features our “Hot Hearth” systems, available in production capacities of up to 500 lb./hr.
“Stepped Hearth” systems for Increased Capacity
Our “Stepped Hearth” line of incinerators provide greater capacities, starting at 350 lb./hr. up to 1000 lb./hr., and can be configured on a custom basis to suit the characteristics and requirements of the system and facility where they are to be installed and needed.
KMB 1600
400 lb/hr – 1,600 lb Capacity
Stepped hearth, large batch (load) system
- Equipment highlights will go here
KMB 2400
600 lb/hr – 2,400 lb Capacity
Stepped hearth, large batch (load) system
- Equipment highlights will go here
KMB 5000
1,250 lb/hr – 5,000 lb Capacity
Stepped hearth, large batch (load) system
- Equipment highlights will go here
Incineration Equipment Comparison
KMB 800 Hot hearth, large batch (load) system
Detail |
KMB 1200 Hot hearth, large batch (load) system
Detail |
KMB 1600 Stepped hearth, large batch (load) system
Detail |
KMB 2400 Stepped hearth, large batch (load) system
Detail |
KMB 5000 Stepped hearth, large batch (load) system
Detail |
|
---|---|---|---|---|---|
Performance Features | |||||
Incineration cycle time | 240-300 min | 240-300 min | 240-300 min | 240-300 min | 240-300 min |
Burn Rate
The hourly rate of combustion is based on a waste stream with an average BTU content of 1000 BTUs/lb. |
200 lbs/hr | 300 lbs/hr | 400 lbs/hr | 600 lbs/hr | 1,250 lbs/hr |
Capacity (Single Load) | 800 lbs | 1200 lbs (545 kg) | 1600 lbs (725 kg) | 2,400 lbs (1088 kg) | 5,000 lbs (2268 kg) |
24 Hr. continuous operation
Heavy-duty insulation and state-of-the-art drafting allows for continuous operation, no cool-downs between cremation cycles. |
|||||
Automatic PLC Operating System
The cremation cycle is controlled by a programmable logic control (PLC) system for complete automation from start to finish. |
|||||
Redundant Controls | |||||
Pollution Control System
Complete combustion is achieved in the Pollution Control Chamber, eliminating smoke and odor. All Keller Manufacturing cremators meet or exceed federal, state/province and local environmental regulations. |
|||||
Standard Equipment Features | |||||
Cylindrical chamber design | |||||
3000ºF (1650ºC) temperature-rated refractory lining | |||||
Recessed floor for fluid control | |||||
High-velocity industrial-grade burners | |||||
Heavy-duty combustion air blower | |||||
Outdoor installation capable | |||||
Individual or communal cremations | |||||
Large animal cremations | |||||
Virtual service capable | |||||
Warranty | One year limited | One year limited | One year limited | One year limited | One year limited |
Safety Certifications
Keller Manufacturing cremation units comply with nationally recognized safety standards and have been tested and listed by Underwriters Laboratories, Inc. (UL) |
#MH47704 | #MH47704 | #MH47704 | #MH47704 | #MH47704 |
Service and Support | |||||
Annual Evaluation and Maintenance (AEM) | Optional | Optional | Optional | Optional | Optional |
Control & combustion upgrades | Optional | Optional | Optional | Optional | Optional |
Equipment Installation | Optional | Optional | Optional | Optional | Optional |
Equipment Commissioning | Included | Included | Included | Included | Included |
Operator Training | Included | Included | Included | Included | Included |
Specifications | |||||
Equipment | Standard “Hot Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired. | Standard “Hot Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired. | Large “Stepped Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired. | Large “Stepped Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired. | Large “Stepped Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired. |
Burn down time | 4-5 hrs. | 4-5 hrs. | 4-5 hrs. | 4-5 hrs. | 4-5 hrs. |
Shipping weight | 15,000 lbs. (6,800 kg) | 19,500 lbs. (8,845 kg) | 25,500 lbs. (11,560 kg) | 36,500 lbs. (16,500 kg) | 42,000 lbs. (19050.88 kg) |
Emissions | The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations. | The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations. | The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations. | The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations. | The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations. |
Incinerator Dimensions | |||||
Chamber volumes: | Primary - 75 ft3 (2.12 m3) Secondary - 70 ft3 (1.98 m3) |
Primary - 86 ft3 (2.43 m3) Secondary - 67 ft3 (1.89 m3) |
Primary - 125 ft3 (3.53 m3) Secondary - 93 ft3 (2.63 m3) |
Primary - 220 ft3 (6.22 m3) Secondary - 185 ft3 (5.23 m3) |
Primary - ? ft3 (? m3) Secondary - ? ft3 (? m3) |
Over-all dimensions | 12’H x 8’W x 10’L (3.66m x 2.44m x 3.05m) | 12’H x 8’W x 11’L (3.66m x 2.44m x 3.35m) | 12’H x 8’W x 14’L (3.66m x 2.44m x 4.27m) | 16’5"H x 9’5"W x 14’L (5.00m x 2.87m x 4.27m) | ?'?"H x ?'?"W x ?'?"L (?m x ?m x ?m) |
Utility Requirements | |||||
Gas: | |||||
Natural gas pressure | 12-15" W.C. (304 to 381mm) | 12-15" W.C. (304 to 381mm) | 12-15" W.C. (304 to 381mm) | 12-15" W.C. (304 to 381mm) | 12-15" W.C. (304 to 381mm) |
Propane pressure | 11" W.C. (288 mm) | 11" W.C. (288 mm) | 11" W.C. (288 mm) | 11" W.C. (288 mm) | 11" W.C. (288 mm) |
Flow rate | 2,000,000 BTU/hr. | 2,000,000 BTU/hr. | 3,000,000 BTU/hr. | 4,000,000 BTU/hr. | ? BTU/hr. |
Electrical: | |||||
Voltage | 220/440 Volts | 220/440 Volts | 220/440 Volts | 220/440 Volts | 220/440 Volts |
Phase | Single or 3 Phase | Single or 3 Phase | Single or 3 Phase | Single or 3 Phase | Single or 3 Phase |
Freq. | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Amps | 1 Phase: 70 Amps 3 Phase 230v/40 Amps, 440v/20 Amps |
1 Phase: 70 Amps 3 Phase 230v/40 Amps, 440v/20 Amps |
1 Phase: 70 Amps 3 Phase 230v/40 Amps, 440v/20 Amps |
1 Phase: 70 Amps 3 Phase 230v/40 Amps, 440v/20 Amps |
1 Phase: 70 Amps 3 Phase 230v/40 Amps, 440v/20 Amps |
Documents | |||||
Machine Drawings | KMB 800 Drawings (PDF) | KMB 1200 Drawings (PDF) | KMB 1600 Drawings (PDF) | KMB 2400 Drawings (PDF) | KMB 5000 Drawings (PDF) |
KMB 800 Hot hearth, large batch (load) system
Detail |
|
---|---|
Performance Features | |
Incineration cycle time | 240-300 min |
Burn Rate
The hourly rate of combustion is based on a waste stream with an average BTU content of 1000 BTUs/lb. |
200 lbs/hr |
Capacity (Single Load) | 800 lbs |
24 Hr. continuous operation
Heavy-duty insulation and state-of-the-art drafting allows for continuous operation, no cool-downs between cremation cycles. |
|
Automatic PLC Operating System
The cremation cycle is controlled by a programmable logic control (PLC) system for complete automation from start to finish. |
|
Redundant Controls | |
Pollution Control System
Complete combustion is achieved in the Pollution Control Chamber, eliminating smoke and odor. All Keller Manufacturing cremators meet or exceed federal, state/province and local environmental regulations. |
|
Standard Equipment Features | |
Cylindrical chamber design | |
3000ºF (1650ºC) temperature-rated refractory lining | |
Recessed floor for fluid control | |
High-velocity industrial-grade burners | |
Heavy-duty combustion air blower | |
Outdoor installation capable | |
Individual or communal cremations | |
Large animal cremations | |
Virtual service capable | |
Warranty | One year limited |
Safety Certifications
Keller Manufacturing cremation units comply with nationally recognized safety standards and have been tested and listed by Underwriters Laboratories, Inc. (UL) |
#MH47704 |
Service and Support | |
Annual Evaluation and Maintenance (AEM) | Optional |
Control & combustion upgrades | Optional |
Equipment Installation | Optional |
Equipment Commissioning | Included |
Operator Training | Included |
Specifications | |
Equipment | Standard “Hot Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired. |
Burn down time | 4-5 hrs. |
Shipping weight | 15,000 lbs. (6,800 kg) |
Emissions | The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations. |
Incinerator Dimensions | |
Chamber volumes: | Primary - 75 ft3 (2.12 m3) Secondary - 70 ft3 (1.98 m3) |
Over-all dimensions | 12’H x 8’W x 10’L (3.66m x 2.44m x 3.05m) |
Utility Requirements | |
Gas: | |
Natural gas pressure | 12-15" W.C. (304 to 381mm) |
Propane pressure | 11" W.C. (288 mm) |
Flow rate | 2,000,000 BTU/hr. |
Electrical: | |
Voltage | 220/440 Volts |
Phase | Single or 3 Phase |
Freq. | 50/60 Hz |
Amps | 1 Phase: 70 Amps 3 Phase 230v/40 Amps, 440v/20 Amps |
Documents | |
Machine Drawings | KMB 800 Drawings (PDF) |
KMB 1200 Hot hearth, large batch (load) system
Detail |
|
---|---|
Performance Features | |
Incineration cycle time | 240-300 min |
Burn Rate
The hourly rate of combustion is based on a waste stream with an average BTU content of 1000 BTUs/lb. |
300 lbs/hr |
Capacity (Single Load) | 1200 lbs (545 kg) |
24 Hr. continuous operation
Heavy-duty insulation and state-of-the-art drafting allows for continuous operation, no cool-downs between cremation cycles. |
|
Automatic PLC Operating System
The cremation cycle is controlled by a programmable logic control (PLC) system for complete automation from start to finish. |
|
Redundant Controls | |
Pollution Control System
Complete combustion is achieved in the Pollution Control Chamber, eliminating smoke and odor. All Keller Manufacturing cremators meet or exceed federal, state/province and local environmental regulations. |
|
Standard Equipment Features | |
Cylindrical chamber design | |
3000ºF (1650ºC) temperature-rated refractory lining | |
Recessed floor for fluid control | |
High-velocity industrial-grade burners | |
Heavy-duty combustion air blower | |
Outdoor installation capable | |
Individual or communal cremations | |
Large animal cremations | |
Virtual service capable | |
Warranty | One year limited |
Safety Certifications
Keller Manufacturing cremation units comply with nationally recognized safety standards and have been tested and listed by Underwriters Laboratories, Inc. (UL) |
#MH47704 |
Service and Support | |
Annual Evaluation and Maintenance (AEM) | Optional |
Control & combustion upgrades | Optional |
Equipment Installation | Optional |
Equipment Commissioning | Included |
Operator Training | Included |
Specifications | |
Equipment | Standard “Hot Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired. |
Burn down time | 4-5 hrs. |
Shipping weight | 19,500 lbs. (8,845 kg) |
Emissions | The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations. |
Incinerator Dimensions | |
Chamber volumes: | Primary - 86 ft3 (2.43 m3) Secondary - 67 ft3 (1.89 m3) |
Over-all dimensions | 12’H x 8’W x 11’L (3.66m x 2.44m x 3.35m) |
Utility Requirements | |
Gas: | |
Natural gas pressure | 12-15" W.C. (304 to 381mm) |
Propane pressure | 11" W.C. (288 mm) |
Flow rate | 2,000,000 BTU/hr. |
Electrical: | |
Voltage | 220/440 Volts |
Phase | Single or 3 Phase |
Freq. | 50/60 Hz |
Amps | 1 Phase: 70 Amps 3 Phase 230v/40 Amps, 440v/20 Amps |
Documents | |
Machine Drawings | KMB 1200 Drawings (PDF) |
KMB 1600 Stepped hearth, large batch (load) system
Detail |
|
---|---|
Performance Features | |
Incineration cycle time | 240-300 min |
Burn Rate
The hourly rate of combustion is based on a waste stream with an average BTU content of 1000 BTUs/lb. |
400 lbs/hr |
Capacity (Single Load) | 1600 lbs (725 kg) |
24 Hr. continuous operation
Heavy-duty insulation and state-of-the-art drafting allows for continuous operation, no cool-downs between cremation cycles. |
|
Automatic PLC Operating System
The cremation cycle is controlled by a programmable logic control (PLC) system for complete automation from start to finish. |
|
Redundant Controls | |
Pollution Control System
Complete combustion is achieved in the Pollution Control Chamber, eliminating smoke and odor. All Keller Manufacturing cremators meet or exceed federal, state/province and local environmental regulations. |
|
Standard Equipment Features | |
Cylindrical chamber design | |
3000ºF (1650ºC) temperature-rated refractory lining | |
Recessed floor for fluid control | |
High-velocity industrial-grade burners | |
Heavy-duty combustion air blower | |
Outdoor installation capable | |
Individual or communal cremations | |
Large animal cremations | |
Virtual service capable | |
Warranty | One year limited |
Safety Certifications
Keller Manufacturing cremation units comply with nationally recognized safety standards and have been tested and listed by Underwriters Laboratories, Inc. (UL) |
#MH47704 |
Service and Support | |
Annual Evaluation and Maintenance (AEM) | Optional |
Control & combustion upgrades | Optional |
Equipment Installation | Optional |
Equipment Commissioning | Included |
Operator Training | Included |
Specifications | |
Equipment | Large “Stepped Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired. |
Burn down time | 4-5 hrs. |
Shipping weight | 25,500 lbs. (11,560 kg) |
Emissions | The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations. |
Incinerator Dimensions | |
Chamber volumes: | Primary - 125 ft3 (3.53 m3) Secondary - 93 ft3 (2.63 m3) |
Over-all dimensions | 12’H x 8’W x 14’L (3.66m x 2.44m x 4.27m) |
Utility Requirements | |
Gas: | |
Natural gas pressure | 12-15" W.C. (304 to 381mm) |
Propane pressure | 11" W.C. (288 mm) |
Flow rate | 3,000,000 BTU/hr. |
Electrical: | |
Voltage | 220/440 Volts |
Phase | Single or 3 Phase |
Freq. | 50/60 Hz |
Amps | 1 Phase: 70 Amps 3 Phase 230v/40 Amps, 440v/20 Amps |
Documents | |
Machine Drawings | KMB 1600 Drawings (PDF) |
KMB 2400 Stepped hearth, large batch (load) system
Detail |
|
---|---|
Performance Features | |
Incineration cycle time | 240-300 min |
Burn Rate
The hourly rate of combustion is based on a waste stream with an average BTU content of 1000 BTUs/lb. |
600 lbs/hr |
Capacity (Single Load) | 2,400 lbs (1088 kg) |
24 Hr. continuous operation
Heavy-duty insulation and state-of-the-art drafting allows for continuous operation, no cool-downs between cremation cycles. |
|
Automatic PLC Operating System
The cremation cycle is controlled by a programmable logic control (PLC) system for complete automation from start to finish. |
|
Redundant Controls | |
Pollution Control System
Complete combustion is achieved in the Pollution Control Chamber, eliminating smoke and odor. All Keller Manufacturing cremators meet or exceed federal, state/province and local environmental regulations. |
|
Standard Equipment Features | |
Cylindrical chamber design | |
3000ºF (1650ºC) temperature-rated refractory lining | |
Recessed floor for fluid control | |
High-velocity industrial-grade burners | |
Heavy-duty combustion air blower | |
Outdoor installation capable | |
Individual or communal cremations | |
Large animal cremations | |
Virtual service capable | |
Warranty | One year limited |
Safety Certifications
Keller Manufacturing cremation units comply with nationally recognized safety standards and have been tested and listed by Underwriters Laboratories, Inc. (UL) |
#MH47704 |
Service and Support | |
Annual Evaluation and Maintenance (AEM) | Optional |
Control & combustion upgrades | Optional |
Equipment Installation | Optional |
Equipment Commissioning | Included |
Operator Training | Included |
Specifications | |
Equipment | Large “Stepped Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired. |
Burn down time | 4-5 hrs. |
Shipping weight | 36,500 lbs. (16,500 kg) |
Emissions | The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations. |
Incinerator Dimensions | |
Chamber volumes: | Primary - 220 ft3 (6.22 m3) Secondary - 185 ft3 (5.23 m3) |
Over-all dimensions | 16’5"H x 9’5"W x 14’L (5.00m x 2.87m x 4.27m) |
Utility Requirements | |
Gas: | |
Natural gas pressure | 12-15" W.C. (304 to 381mm) |
Propane pressure | 11" W.C. (288 mm) |
Flow rate | 4,000,000 BTU/hr. |
Electrical: | |
Voltage | 220/440 Volts |
Phase | Single or 3 Phase |
Freq. | 50/60 Hz |
Amps | 1 Phase: 70 Amps 3 Phase 230v/40 Amps, 440v/20 Amps |
Documents | |
Machine Drawings | KMB 2400 Drawings (PDF) |
KMB 5000 Stepped hearth, large batch (load) system
Detail |
|
---|---|
Performance Features | |
Incineration cycle time | 240-300 min |
Burn Rate
The hourly rate of combustion is based on a waste stream with an average BTU content of 1000 BTUs/lb. |
1,250 lbs/hr |
Capacity (Single Load) | 5,000 lbs (2268 kg) |
24 Hr. continuous operation
Heavy-duty insulation and state-of-the-art drafting allows for continuous operation, no cool-downs between cremation cycles. |
|
Automatic PLC Operating System
The cremation cycle is controlled by a programmable logic control (PLC) system for complete automation from start to finish. |
|
Redundant Controls | |
Pollution Control System
Complete combustion is achieved in the Pollution Control Chamber, eliminating smoke and odor. All Keller Manufacturing cremators meet or exceed federal, state/province and local environmental regulations. |
|
Standard Equipment Features | |
Cylindrical chamber design | |
3000ºF (1650ºC) temperature-rated refractory lining | |
Recessed floor for fluid control | |
High-velocity industrial-grade burners | |
Heavy-duty combustion air blower | |
Outdoor installation capable | |
Individual or communal cremations | |
Large animal cremations | |
Virtual service capable | |
Warranty | One year limited |
Safety Certifications
Keller Manufacturing cremation units comply with nationally recognized safety standards and have been tested and listed by Underwriters Laboratories, Inc. (UL) |
#MH47704 |
Service and Support | |
Annual Evaluation and Maintenance (AEM) | Optional |
Control & combustion upgrades | Optional |
Equipment Installation | Optional |
Equipment Commissioning | Included |
Operator Training | Included |
Specifications | |
Equipment | Large “Stepped Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired. |
Burn down time | 4-5 hrs. |
Shipping weight | 42,000 lbs. (19050.88 kg) |
Emissions | The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations. |
Incinerator Dimensions | |
Chamber volumes: | Primary - ? ft3 (? m3) Secondary - ? ft3 (? m3) |
Over-all dimensions | ?'?"H x ?'?"W x ?'?"L (?m x ?m x ?m) |
Utility Requirements | |
Gas: | |
Natural gas pressure | 12-15" W.C. (304 to 381mm) |
Propane pressure | 11" W.C. (288 mm) |
Flow rate | ? BTU/hr. |
Electrical: | |
Voltage | 220/440 Volts |
Phase | Single or 3 Phase |
Freq. | 50/60 Hz |
Amps | 1 Phase: 70 Amps 3 Phase 230v/40 Amps, 440v/20 Amps |
Documents | |
Machine Drawings | KMB 5000 Drawings (PDF) |
Frequently Asked Questions
Yes. Upon notification from the customer that the installation is complete, a Keller technician will travel to the facility to place the unit in operation. Our technician will spend up to three days at the site curing the refractory lining of the incinerator, starting up the unit, adjusting air and gas settings and proving all systems. To complete the start-up the technician will perform a cremation and train incineration personnel in the simple operation. It is important that a cremation be available for training at start up.
We warrant our equipment to be free of defects in workmanship for two years and our staff is available around the clock to provide technical assistance and operating support. The Operating & Maintenance Manual describes the function of all components and is invaluable for troubleshooting. We stock a complete line of replacement parts and major components and our Service Department is available for service and repairs on all makes of cremation equipment.
Standard to the KMB line of incinerators is a proven and tested automatic operating system with color touch screen control. Load the body and container in the primary chamber, set the timer and press the Start button to begin the cycle. The system is programmed to begin a 45-second purge cycle before igniting the secondary chamber burner to start the preheat cycle. Once the proper temperature is reached in the pollution control chamber, the primary burner is ignited to begin the cremation cycle. Upon completion of the cremation the system advances to the cool down cycle at which time the burners shut down and clean out of the cremated remains can be made.
Complete combustion is achieved in the KMB line’s temperature-controlled large secondary chamber. Greater than 99% of volatilized carbon created in the combustion process is converted to carbon dioxide. In addition, an Opacity Sensor is located at the base of the stack to monitor the clarity of the exhaust gases. Once the exhaust gases reach 20% opacity, the PLC automatically shuts down the primary burner and adjusts combustion air supply to slow the combustion rate and prevent visible emissions from exiting the stack.
We have a 60 year history of manufacturing and servicing industry equipment worldwide.
Keller has gained a reputation for being a worldwide leader in the design and manufacture of combustion systems. Based in Central Florida, we have manufactured and put into operation over two thousand (2,000) installations worldwide.
We are proud members of CANA and ICCFA:
How may we help you?
Our experienced professional team can help you with any cremation or incineration project anywhere in the world.
Need a quote or looking for more info? We can help.
We’ll call you back at your convenience.
Schedule a Service Appointment
To schedule service or consult with a Keller Mechanical Technician, give us a call, or fill out the following form and a member of our staff will be in touch with you shortly.
Need a quote or looking for more info? We can help.
We’ll call you back at your convenience.
Schedule a Service Appointment
To schedule service or consult with a Keller Mechanical Technician, give us a call, or fill out the following form and a member of our staff will be in touch with you shortly.
Prefer a more traditional method?
Give us a call, shoot us an email, or send us some snail mail. We’ll be glad to hear from you.