• Skip to primary navigation
  • Skip to main content
Keller Manufacturing Logo

Keller Manufacturing

The Absolute Best in Crematories and Incinerators

  • Cremation
    • Human Cremation Equipment
      • Overview
      • KMH 1100-200
      • KMH 1100-300
      • KMH 1100-400
    • Animal Cremation Equipment
      • Overview
      • KMA 1200-75
      • KMA 1200-125
      • KMA 1200-200
      • KMA 1200-300
      • KMA 1200-400
      • KMA 1200-500 2C
      • KMA 1200-1000 4C
    • Cremation Accessory Equipment
      • Hydraulic Lift Table and Scale
      • Remains Processor
      • Processing Station
  • Waste Incineration
    • Overview
    • KMB 800
    • KMB 1200
    • KMB 1600
    • KMB 2400
    • KMB 5000
  • Parts and Supplies
  • Services
    • Equipment Maintenance, Service & Repairs
    • Equipment Installation, Commissioning and Operator Training
    • Equipment Financing
  • About
  • Contact
    • Sales
    • Service
    • Employment
Model image

Medical Waste Incinerators

Keller Manufacturing offers a complete range of medical waste incinerators and services from the manufacturing of incinerators, thermal and recuperative thermal oxidizers, stacks, breaching, pollution control equipment and charging systems, to complete rebuilds of existing systems, technical consulting and engineering, waste analysis, environmental permitting and testing/certification.

  • Overview
  • Incineration Equipment
  • Equipment Comparison
  • FAQ
Interior view of a medical bio waste facility with batch incineration units

Industry Expertise

We are experienced in the areas of medical, pathological and solid waste incineration as well as in the application of our technologies to other industries such as chemical, industrial, VOC and liquid waste treatment as well.

Equipment drawing blueprint overlaying a live equipment photo

A Full Line of Equipment

All of our incineration equipment operates on a geometrically similar construction and design principal and can be configured for solids, liquids and gaseous wastes, while providing features and benefits which cannot be matched in total by any other equipment manufacturer.

Incineration Equipment
White smoke billows from tall stacks against a blue sky

Emissions requirements

When emissions requirements dictate that more than the effects of good combustion are needed, we are positioned and experienced to supply integrated systems and/or retrofit existing systems to meet virtually any demand.

Medical Waste Incinerators

Standard “Hot Hearth” systems

Our standard line of solid waste incineration equipment features our “Hot Hearth” systems, available in production capacities of up to 500 lb./hr.

Model image

KMB 800

200 lb/hr – 800 lb Capacity

Hot hearth, large batch (load) system

Unit Detail
  • Equipment highlights will go here

Compare Features

Model image

KMB 1200

300 lb/hr – 1,200 lb Capacity

Hot hearth, large batch (load) system

Unit Detail
  • Equipment highlights will go here

Compare Features

“Stepped Hearth” systems for Increased Capacity

Our “Stepped Hearth” line of incinerators provide greater capacities, starting at 350 lb./hr. up to 1000 lb./hr., and can be configured on a custom basis to suit the characteristics and requirements of the system and facility where they are to be installed and needed.

Model image

KMB 1600

400 lb/hr – 1,600 lb Capacity

Stepped hearth, large batch (load) system

Unit Detail
  • Equipment highlights will go here

Compare Features

Model image

KMB 2400

600 lb/hr – 2,400 lb Capacity

Stepped hearth, large batch (load) system

Unit Detail
  • Equipment highlights will go here

Compare Features

Model image

KMB 5000

1,250 lb/hr – 5,000 lb Capacity

Stepped hearth, large batch (load) system

Unit Detail
  • Equipment highlights will go here

Compare Features

Incineration Equipment Comparison

Model image
KMB 800 Hot hearth, large batch (load) system
Detail
Model image
KMB 1200 Hot hearth, large batch (load) system
Detail
Model image
KMB 1600 Stepped hearth, large batch (load) system
Detail
Model image
KMB 2400 Stepped hearth, large batch (load) system
Detail
Model image
KMB 5000 Stepped hearth, large batch (load) system
Detail
Performance Features          
Incineration cycle time 240-300 min 240-300 min 240-300 min 240-300 min 240-300 min
Burn Rate

The hourly rate of combustion is based on a waste stream with an average BTU content of 1000 BTUs/lb.

200 lbs/hr 300 lbs/hr 400 lbs/hr 600 lbs/hr 1,250 lbs/hr
Capacity (Single Load) 800 lbs 1200 lbs (545 kg) 1600 lbs (725 kg) 2,400 lbs (1088 kg) 5,000 lbs (2268 kg)
24 Hr. continuous operation

Heavy-duty insulation and state-of-the-art drafting allows for continuous operation, no cool-downs between cremation cycles.

yes yes yes yes yes
Automatic PLC Operating System

The cremation cycle is controlled by a programmable logic control (PLC) system for complete automation from start to finish.

yes yes yes yes yes
Redundant Controls yes yes yes yes yes
Pollution Control System

Complete combustion is achieved in the Pollution Control Chamber, eliminating smoke and odor. All Keller Manufacturing cremators meet or exceed federal, state/province and local environmental regulations.

yes yes yes yes yes
Standard Equipment Features          
Cylindrical chamber design yes yes yes yes yes
3000ºF (1650ºC) temperature-rated refractory lining yes yes yes yes yes
Recessed floor for fluid control yes yes yes yes yes
High-velocity industrial-grade burners yes yes yes yes yes
Heavy-duty combustion air blower yes yes yes yes yes
Outdoor installation capable yes yes yes yes yes
Individual or communal cremations yes yes yes yes yes
Large animal cremations yes yes yes yes yes
Virtual service capable yes yes yes yes yes
Warranty One year limited One year limited One year limited One year limited One year limited
Safety Certifications

Keller Manufacturing cremation units comply with nationally recognized safety standards and have been tested and listed by Underwriters Laboratories, Inc. (UL)

#MH47704 #MH47704 #MH47704 #MH47704 #MH47704
Service and Support          
Annual Evaluation and Maintenance (AEM) Optional Optional Optional Optional Optional
Control & combustion upgrades Optional Optional Optional Optional Optional
Equipment Installation Optional Optional Optional Optional Optional
Equipment Commissioning Included Included Included Included Included
Operator Training Included Included Included Included Included
Specifications          
Equipment Standard “Hot Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired. Standard “Hot Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired. Large “Stepped Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired. Large “Stepped Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired. Large “Stepped Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired.
Burn down time 4-5 hrs. 4-5 hrs. 4-5 hrs. 4-5 hrs. 4-5 hrs.
Shipping weight 15,000 lbs. (6,800 kg) 19,500 lbs. (8,845 kg) 25,500 lbs. (11,560 kg) 36,500 lbs. (16,500 kg) 42,000 lbs. (19050.88 kg)
Emissions The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations. The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations. The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations. The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations. The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations.
Incinerator Dimensions          
Chamber volumes: Primary - 75 ft3 (2.12 m3)
Secondary - 70 ft3 (1.98 m3)
Primary - 86 ft3 (2.43 m3)
Secondary - 67 ft3 (1.89 m3)
Primary - 125 ft3 (3.53 m3)
Secondary - 93 ft3 (2.63 m3)
Primary - 220 ft3 (6.22 m3)
Secondary - 185 ft3 (5.23 m3)
Primary - ? ft3 (? m3)
Secondary - ? ft3 (? m3)
Over-all dimensions 12’H x 8’W x 10’L (3.66m x 2.44m x 3.05m) 12’H x 8’W x 11’L (3.66m x 2.44m x 3.35m) 12’H x 8’W x 14’L (3.66m x 2.44m x 4.27m) 16’5"H x 9’5"W x 14’L (5.00m x 2.87m x 4.27m) ?'?"H x ?'?"W x ?'?"L (?m x ?m x ?m)
Utility Requirements          
Gas:          
Natural gas pressure 12-15" W.C. (304 to 381mm) 12-15" W.C. (304 to 381mm) 12-15" W.C. (304 to 381mm) 12-15" W.C. (304 to 381mm) 12-15" W.C. (304 to 381mm)
Propane pressure 11" W.C. (288 mm) 11" W.C. (288 mm) 11" W.C. (288 mm) 11" W.C. (288 mm) 11" W.C. (288 mm)
Flow rate 2,000,000 BTU/hr. 2,000,000 BTU/hr. 3,000,000 BTU/hr. 4,000,000 BTU/hr. ? BTU/hr.
Electrical:          
Voltage 220/440 Volts 220/440 Volts 220/440 Volts 220/440 Volts 220/440 Volts
Phase Single or 3 Phase Single or 3 Phase Single or 3 Phase Single or 3 Phase Single or 3 Phase
Freq. 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Amps 1 Phase: 70 Amps
3 Phase 230v/40 Amps, 440v/20 Amps
1 Phase: 70 Amps
3 Phase 230v/40 Amps, 440v/20 Amps
1 Phase: 70 Amps
3 Phase 230v/40 Amps, 440v/20 Amps
1 Phase: 70 Amps
3 Phase 230v/40 Amps, 440v/20 Amps
1 Phase: 70 Amps
3 Phase 230v/40 Amps, 440v/20 Amps
Documents          
Machine Drawings KMB 800 Drawings (PDF) KMB 1200 Drawings (PDF) KMB 1600 Drawings (PDF) KMB 2400 Drawings (PDF) KMB 5000 Drawings (PDF)
Model image
KMB 800 Hot hearth, large batch (load) system
Detail
Performance Features
Incineration cycle time 240-300 min
Burn Rate

The hourly rate of combustion is based on a waste stream with an average BTU content of 1000 BTUs/lb.

200 lbs/hr
Capacity (Single Load) 800 lbs
24 Hr. continuous operation

Heavy-duty insulation and state-of-the-art drafting allows for continuous operation, no cool-downs between cremation cycles.

yes
Automatic PLC Operating System

The cremation cycle is controlled by a programmable logic control (PLC) system for complete automation from start to finish.

yes
Redundant Controls yes
Pollution Control System

Complete combustion is achieved in the Pollution Control Chamber, eliminating smoke and odor. All Keller Manufacturing cremators meet or exceed federal, state/province and local environmental regulations.

yes
Standard Equipment Features
Cylindrical chamber design yes
3000ºF (1650ºC) temperature-rated refractory lining yes
Recessed floor for fluid control yes
High-velocity industrial-grade burners yes
Heavy-duty combustion air blower yes
Outdoor installation capable yes
Individual or communal cremations yes
Large animal cremations yes
Virtual service capable yes
Warranty One year limited
Safety Certifications

Keller Manufacturing cremation units comply with nationally recognized safety standards and have been tested and listed by Underwriters Laboratories, Inc. (UL)

#MH47704
Service and Support
Annual Evaluation and Maintenance (AEM) Optional
Control & combustion upgrades Optional
Equipment Installation Optional
Equipment Commissioning Included
Operator Training Included
Specifications
Equipment Standard “Hot Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired.
Burn down time 4-5 hrs.
Shipping weight 15,000 lbs. (6,800 kg)
Emissions The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations.
Incinerator Dimensions  
Chamber volumes: Primary - 75 ft3 (2.12 m3)
Secondary - 70 ft3 (1.98 m3)
Over-all dimensions 12’H x 8’W x 10’L (3.66m x 2.44m x 3.05m)
Utility Requirements
Gas:  
Natural gas pressure 12-15" W.C. (304 to 381mm)
Propane pressure 11" W.C. (288 mm)
Flow rate 2,000,000 BTU/hr.
Electrical:  
Voltage 220/440 Volts
Phase Single or 3 Phase
Freq. 50/60 Hz
Amps 1 Phase: 70 Amps
3 Phase 230v/40 Amps, 440v/20 Amps
Documents
Machine Drawings KMB 800 Drawings (PDF)
Model image
KMB 1200 Hot hearth, large batch (load) system
Detail
Performance Features
Incineration cycle time 240-300 min
Burn Rate

The hourly rate of combustion is based on a waste stream with an average BTU content of 1000 BTUs/lb.

300 lbs/hr
Capacity (Single Load) 1200 lbs (545 kg)
24 Hr. continuous operation

Heavy-duty insulation and state-of-the-art drafting allows for continuous operation, no cool-downs between cremation cycles.

yes
Automatic PLC Operating System

The cremation cycle is controlled by a programmable logic control (PLC) system for complete automation from start to finish.

yes
Redundant Controls yes
Pollution Control System

Complete combustion is achieved in the Pollution Control Chamber, eliminating smoke and odor. All Keller Manufacturing cremators meet or exceed federal, state/province and local environmental regulations.

yes
Standard Equipment Features
Cylindrical chamber design yes
3000ºF (1650ºC) temperature-rated refractory lining yes
Recessed floor for fluid control yes
High-velocity industrial-grade burners yes
Heavy-duty combustion air blower yes
Outdoor installation capable yes
Individual or communal cremations yes
Large animal cremations yes
Virtual service capable yes
Warranty One year limited
Safety Certifications

Keller Manufacturing cremation units comply with nationally recognized safety standards and have been tested and listed by Underwriters Laboratories, Inc. (UL)

#MH47704
Service and Support
Annual Evaluation and Maintenance (AEM) Optional
Control & combustion upgrades Optional
Equipment Installation Optional
Equipment Commissioning Included
Operator Training Included
Specifications
Equipment Standard “Hot Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired.
Burn down time 4-5 hrs.
Shipping weight 19,500 lbs. (8,845 kg)
Emissions The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations.
Incinerator Dimensions  
Chamber volumes: Primary - 86 ft3 (2.43 m3)
Secondary - 67 ft3 (1.89 m3)
Over-all dimensions 12’H x 8’W x 11’L (3.66m x 2.44m x 3.35m)
Utility Requirements
Gas:  
Natural gas pressure 12-15" W.C. (304 to 381mm)
Propane pressure 11" W.C. (288 mm)
Flow rate 2,000,000 BTU/hr.
Electrical:  
Voltage 220/440 Volts
Phase Single or 3 Phase
Freq. 50/60 Hz
Amps 1 Phase: 70 Amps
3 Phase 230v/40 Amps, 440v/20 Amps
Documents
Machine Drawings KMB 1200 Drawings (PDF)
Model image
KMB 1600 Stepped hearth, large batch (load) system
Detail
Performance Features
Incineration cycle time 240-300 min
Burn Rate

The hourly rate of combustion is based on a waste stream with an average BTU content of 1000 BTUs/lb.

400 lbs/hr
Capacity (Single Load) 1600 lbs (725 kg)
24 Hr. continuous operation

Heavy-duty insulation and state-of-the-art drafting allows for continuous operation, no cool-downs between cremation cycles.

yes
Automatic PLC Operating System

The cremation cycle is controlled by a programmable logic control (PLC) system for complete automation from start to finish.

yes
Redundant Controls yes
Pollution Control System

Complete combustion is achieved in the Pollution Control Chamber, eliminating smoke and odor. All Keller Manufacturing cremators meet or exceed federal, state/province and local environmental regulations.

yes
Standard Equipment Features
Cylindrical chamber design yes
3000ºF (1650ºC) temperature-rated refractory lining yes
Recessed floor for fluid control yes
High-velocity industrial-grade burners yes
Heavy-duty combustion air blower yes
Outdoor installation capable yes
Individual or communal cremations yes
Large animal cremations yes
Virtual service capable yes
Warranty One year limited
Safety Certifications

Keller Manufacturing cremation units comply with nationally recognized safety standards and have been tested and listed by Underwriters Laboratories, Inc. (UL)

#MH47704
Service and Support
Annual Evaluation and Maintenance (AEM) Optional
Control & combustion upgrades Optional
Equipment Installation Optional
Equipment Commissioning Included
Operator Training Included
Specifications
Equipment Large “Stepped Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired.
Burn down time 4-5 hrs.
Shipping weight 25,500 lbs. (11,560 kg)
Emissions The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations.
Incinerator Dimensions  
Chamber volumes: Primary - 125 ft3 (3.53 m3)
Secondary - 93 ft3 (2.63 m3)
Over-all dimensions 12’H x 8’W x 14’L (3.66m x 2.44m x 4.27m)
Utility Requirements
Gas:  
Natural gas pressure 12-15" W.C. (304 to 381mm)
Propane pressure 11" W.C. (288 mm)
Flow rate 3,000,000 BTU/hr.
Electrical:  
Voltage 220/440 Volts
Phase Single or 3 Phase
Freq. 50/60 Hz
Amps 1 Phase: 70 Amps
3 Phase 230v/40 Amps, 440v/20 Amps
Documents
Machine Drawings KMB 1600 Drawings (PDF)
Model image
KMB 2400 Stepped hearth, large batch (load) system
Detail
Performance Features
Incineration cycle time 240-300 min
Burn Rate

The hourly rate of combustion is based on a waste stream with an average BTU content of 1000 BTUs/lb.

600 lbs/hr
Capacity (Single Load) 2,400 lbs (1088 kg)
24 Hr. continuous operation

Heavy-duty insulation and state-of-the-art drafting allows for continuous operation, no cool-downs between cremation cycles.

yes
Automatic PLC Operating System

The cremation cycle is controlled by a programmable logic control (PLC) system for complete automation from start to finish.

yes
Redundant Controls yes
Pollution Control System

Complete combustion is achieved in the Pollution Control Chamber, eliminating smoke and odor. All Keller Manufacturing cremators meet or exceed federal, state/province and local environmental regulations.

yes
Standard Equipment Features
Cylindrical chamber design yes
3000ºF (1650ºC) temperature-rated refractory lining yes
Recessed floor for fluid control yes
High-velocity industrial-grade burners yes
Heavy-duty combustion air blower yes
Outdoor installation capable yes
Individual or communal cremations yes
Large animal cremations yes
Virtual service capable yes
Warranty One year limited
Safety Certifications

Keller Manufacturing cremation units comply with nationally recognized safety standards and have been tested and listed by Underwriters Laboratories, Inc. (UL)

#MH47704
Service and Support
Annual Evaluation and Maintenance (AEM) Optional
Control & combustion upgrades Optional
Equipment Installation Optional
Equipment Commissioning Included
Operator Training Included
Specifications
Equipment Large “Stepped Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired.
Burn down time 4-5 hrs.
Shipping weight 36,500 lbs. (16,500 kg)
Emissions The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations.
Incinerator Dimensions  
Chamber volumes: Primary - 220 ft3 (6.22 m3)
Secondary - 185 ft3 (5.23 m3)
Over-all dimensions 16’5"H x 9’5"W x 14’L (5.00m x 2.87m x 4.27m)
Utility Requirements
Gas:  
Natural gas pressure 12-15" W.C. (304 to 381mm)
Propane pressure 11" W.C. (288 mm)
Flow rate 4,000,000 BTU/hr.
Electrical:  
Voltage 220/440 Volts
Phase Single or 3 Phase
Freq. 50/60 Hz
Amps 1 Phase: 70 Amps
3 Phase 230v/40 Amps, 440v/20 Amps
Documents
Machine Drawings KMB 2400 Drawings (PDF)
Model image
KMB 5000 Stepped hearth, large batch (load) system
Detail
Performance Features
Incineration cycle time 240-300 min
Burn Rate

The hourly rate of combustion is based on a waste stream with an average BTU content of 1000 BTUs/lb.

1,250 lbs/hr
Capacity (Single Load) 5,000 lbs (2268 kg)
24 Hr. continuous operation

Heavy-duty insulation and state-of-the-art drafting allows for continuous operation, no cool-downs between cremation cycles.

yes
Automatic PLC Operating System

The cremation cycle is controlled by a programmable logic control (PLC) system for complete automation from start to finish.

yes
Redundant Controls yes
Pollution Control System

Complete combustion is achieved in the Pollution Control Chamber, eliminating smoke and odor. All Keller Manufacturing cremators meet or exceed federal, state/province and local environmental regulations.

yes
Standard Equipment Features
Cylindrical chamber design yes
3000ºF (1650ºC) temperature-rated refractory lining yes
Recessed floor for fluid control yes
High-velocity industrial-grade burners yes
Heavy-duty combustion air blower yes
Outdoor installation capable yes
Individual or communal cremations yes
Large animal cremations yes
Virtual service capable yes
Warranty One year limited
Safety Certifications

Keller Manufacturing cremation units comply with nationally recognized safety standards and have been tested and listed by Underwriters Laboratories, Inc. (UL)

#MH47704
Service and Support
Annual Evaluation and Maintenance (AEM) Optional
Control & combustion upgrades Optional
Equipment Installation Optional
Equipment Commissioning Included
Operator Training Included
Specifications
Equipment Large “Stepped Hearth” Incinerator; Natural Gas, Propane (LP) or Oil fired.
Burn down time 4-5 hrs.
Shipping weight 42,000 lbs. (19050.88 kg)
Emissions The Keller Manufacturing Cremation Equipment cremator shall meet or exceed federal, state/province and local environmental regulations.
Incinerator Dimensions  
Chamber volumes: Primary - ? ft3 (? m3)
Secondary - ? ft3 (? m3)
Over-all dimensions ?'?"H x ?'?"W x ?'?"L (?m x ?m x ?m)
Utility Requirements
Gas:  
Natural gas pressure 12-15" W.C. (304 to 381mm)
Propane pressure 11" W.C. (288 mm)
Flow rate ? BTU/hr.
Electrical:  
Voltage 220/440 Volts
Phase Single or 3 Phase
Freq. 50/60 Hz
Amps 1 Phase: 70 Amps
3 Phase 230v/40 Amps, 440v/20 Amps
Documents
Machine Drawings KMB 5000 Drawings (PDF)

Frequently Asked Questions

Do You Provide Start Up & Training?

Yes. Upon notification from the customer that the installation is complete, a Keller technician will travel to the facility to place the unit in operation. Our technician will spend up to three days at the site curing the refractory lining of the incinerator, starting up the unit, adjusting air and gas settings and proving all systems. To complete the start-up the technician will perform a cremation and train incineration personnel in the simple operation. It is important that a cremation be available for training at start up.

What Do You Provide For Warranty & Service?

We warrant our equipment to be free of defects in workmanship for two years and our staff is available around the clock to provide technical assistance and operating support. The Operating & Maintenance Manual describes the function of all components and is invaluable for troubleshooting. We stock a complete line of replacement parts and major components and our Service Department is available for service and repairs on all makes of cremation equipment.

Is Your Operating System Automatic?

Standard to the KMB line of incinerators is a proven and tested automatic operating system with color touch screen control. Load the body and container in the primary chamber, set the timer and press the Start button to begin the cycle. The system is programmed to begin a 45-second purge cycle before igniting the secondary chamber burner to start the preheat cycle. Once the proper temperature is reached in the pollution control chamber, the primary burner is ignited to begin the cremation cycle. Upon completion of the cremation the system advances to the cool down cycle at which time the burners shut down and clean out of the cremated remains can be made.

Do We Have To Worry About Any Visible Emissions?

Complete combustion is achieved in the KMB line’s temperature-controlled large secondary chamber. Greater than 99% of volatilized carbon created in the combustion process is converted to carbon dioxide. In addition, an Opacity Sensor is located at the base of the stack to monitor the clarity of the exhaust gases. Once the exhaust gases reach 20% opacity, the PLC automatically shuts down the primary burner and adjusts combustion air supply to slow the combustion rate and prevent visible emissions from exiting the stack.

We have a 60 year history of manufacturing and servicing industry equipment worldwide.

Keller has gained a reputation for being a worldwide leader in the design and manufacture of combustion systems. Based in Central Florida, we have manufactured and put into operation over two thousand (2,000) installations worldwide.

Raymond Bounds Avatar Raymond Bounds

Great work quality and everyone is friendly

bradford pry Avatar bradford pry

We are proud members of CANA and ICCFA:

CANA Logo
ICCFA Logo

How may we help you?

Our experienced professional team can help you with any cremation or incineration project anywhere in the world. 

Request InfoRequest a CallSchedule Service

Need a quote or looking for more info? We can help.

Periodic news, updates, and special offers from Keller Manufacturing direct to your inbox.
Loading

We’ll call you back at your convenience.

Periodic news, updates, and special offers from Keller Manufacturing direct to your inbox.
Loading

Schedule a Service Appointment

To schedule service or consult with a Keller Mechanical Technician, give us a call, or fill out the following form and a member of our staff will be in touch with you shortly.

About Your Request

Periodic news, updates, and special offers from Keller Manufacturing direct to your inbox.
Loading
Request Information

Need a quote or looking for more info? We can help.

Periodic news, updates, and special offers from Keller Manufacturing direct to your inbox.
Loading
Request a Call

We’ll call you back at your convenience.

Periodic news, updates, and special offers from Keller Manufacturing direct to your inbox.
Loading
Schedule Service

Schedule a Service Appointment

To schedule service or consult with a Keller Mechanical Technician, give us a call, or fill out the following form and a member of our staff will be in touch with you shortly.

About Your Request

Periodic news, updates, and special offers from Keller Manufacturing direct to your inbox.
Loading

Prefer a more traditional method?

Give us a call, shoot us an email, or send us some snail mail. We’ll be glad to hear from you.

(863) 937-8928

Email Sales

4442 Holden Rd
Lakeland, FL 33811

You are here: Home / Landing Pages / Medical Waste Incinerators

Coordinate with our expert staff on your facility's requirements. Contact Us

Keller Manufacturing

Copyright © 2025Keller Manufacturing, Inc. · Privacy Policy · Contact Us